Digital Flow Sensor for Water


Series KLFMW
TypeKLFMW 4KLFMW 16KLFMW 40KLFMW 100
MediumWater, Ethylene Glycol Aqueous Solution (Viscosity Below 3 cP)
Detection MethodKarman Vortex Street Type
Rate Flow Range (L/min)0.5~42~165~4010~100
Display Flow Range (L/min)0.35~5.50
(Less than 0.35, it will display 0.00)
1.70~22.00
(Less than 1.7, it will display 0.0)
3.5~55.0
(Less than 3.5, it will display 0.0)
7~140
(Less than 7, it will display 0)
Set Flow Range (L/min)0.35~5.501.70~22.003.5~55.07~140
Minimum Setting Unit0.010.010.11
Using Fluid temperature-22~110℃ (No condensation, no freezing)
Display UnitInstantaneous flow rate L/min, cumulative flow rate L
AccuracyDisplay value: ±3% F.S. / Analog output: ±3% F.S.
Repeat Accuracy±2% F.S.
Temperature Characteristics±5% F.S.(25℃)
Using Pressure Range0~1 MPa
Max. Pressure1.5 MPa
Pressure Loss45 kPa or less at maximum flow rate
Accumulated Flow Range99999999.9L999999999L
HysteresisVariable
Power SupplyDC12~24V±10%
Current Consumption≦50mA