Pneumatic Solenoid Valves Manufacturer - Kao Lu
> Products > Proportional Valve > Flow proportional > PM-300 Medium Flow Proportional Valve Driver+FC-300 Medium Flow Stepper-Controlled Proportional Valves
Product Description
PM-300 provides FC-300 with the required power and control signal (step and direction). It controls the step of a bipolar stepper motor with an analogue signal (1-10 Vdc/4-20mA).

FC-300 Utilizing the industry’s most robust and powerful linear actuator, the high-flow stepper-controlled proportional valve outperforms the competition in performance and durability. This valve is ideal in critical applications such as gas delivery, medical, analytical, and industrial automation requiring high resolution, high flow, and low hysteresis. In addition, the unique design allows for custom flow profiles when required.

Potential Applications:
• Medical/Analytical/Industrial Gas Mixing
• Anesthesia Equipment
• Precision Flow Control
• Cuff/Bladder Pressure Control
• Process Flow Control
• Variable Speed Control
• Automation of Needle Valve
Product Specification

PM-300

Input signal
DC0-10V / 4-20mA
Supply pressure max
7kg/cm2
Supply
DC24V (≦5W)
Linearity
±0.5% F.S.
Repeatability
±0.1% F.S.
Command Resolution
0.1 mA / 0.03 V
Flow rate
300 l/min @ 7kg/cm2
Temp. Range(Operating)
0-60℃

 

FC-300

Valve Type
2-Way Proportional Needle valves
Configuration
square body with 1/8”PT ports
Typical Cycle Time for Full Travel
1 seconds at 100% duty cycle;
0.25 seconds at 25% duty cycle
(full open to full close or full close to full open)
Medium
Compatible gases and liquids
Wetted Material
Aluminum and FKM*
Pressure Range
Vac to 7 kg/cm2 (Vac to 7 bar)*
Flow Range
0~300 l/min @ 7 kg/cm2
Flow Resolution
0.50 slpm /step
Position Resolution
0.02 mm/step
Temperature Range
32 to 184°F (0 to 84°C)
Driver
Bipolar chopper drive required
Supply Voltage to Motor
5 VDC
Response Time
2.5 sec. fully-open to fully-closed*
Mounting
In-line, manifold or cartridge
Power Consumption
3.85 watts nominal only during adjustment.
Zero power consumption to maintain position.
Seals
FKM standard. Others available.